Free download · Updated 2026-05-19

    THE G3 CHEAT SHEET

    One page. Every gas property, clearance, venting category, and pipe-sizing rule that shows up on the TSSA G3 exam. Print it, tape it to your locker, read it the night before.

    Rooted in CSA B149.1 (current edition, adopted under Ontario Reg. 212/01) and the TSSA G3 Exam Blueprint. Verify every clearance against the appliance rating plate and the current code before installation.

    1. Gas properties (memorize cold)

    PropertyNatural gasPropane
    Specific gravity (air = 1)0.60 (lighter)1.52 (heavier)
    Heating value~1,000 BTU/ft³~2,500 BTU/ft³
    Flammability limits (LEL–UEL)4% – 15%2.15% – 9.6%
    Ignition temperature~1,163 °F (630 °C)~920 °F (493 °C)
    Air required for combustion10 ft³/ft³25 ft³/ft³
    OdorantMercaptanEthyl mercaptan

    Exam trap: propane pools in low spots (basements, pits). Natural gas rises. Ventilation strategy is different for each.

    2. Clearances (default values — always check the plate)

    • Type B vent connector to combustibles: 6 in (150 mm) default.
    • Single-wall vent connector to combustibles: 6 in (150 mm), or per manufacturer.
    • Regulator vent terminal to any building air intake: 3 m (10 ft) minimum.
    • Vent termination to mechanical air intake: 1.8 m (6 ft) minimum.
    • Vent termination to a window or door that opens: 300 mm (1 ft) minimum, side or below opening.
    • Vent termination above grade / anticipated snow line: 300 mm (1 ft) minimum, more in snow country.
    • Gas meter clearance to source of ignition: 1 m (3 ft).

    3. Venting categories (know all four)

    CategoryPressureCondensing?Typical vent material
    INegativeNoType B vent (natural draft)
    IINegativeYesAL29-4C stainless (rare)
    IIIPositiveNoAL29-4C, listed positive-pressure
    IVPositiveYesPVC / CPVC / polypropylene (per mfr)

    4. Combustion air (rule-of-thumb)

    • All-air-from-inside: 50 ft³ per 1,000 BTU/h input of all appliances in the space.
    • Two-opening method (outdoor air): one high, one low, each sized at 1 in² per 4,000 BTU/h.
    • One-opening method (outdoor air): 1 in² per 3,000 BTU/h, opening within 12 in of the ceiling.

    5. Pipe sizing quick reference

    Pipe sizing is table lookup, not calculation. You need three inputs:

    • Total connected load in BTU/h (sum all appliance input ratings).
    • Developed length from meter to farthest appliance.
    • Allowable pressure drop (typically 0.5" WC for < 2 psi systems).

    Look up the row (length) and column (BTU/h) in the CSA B149.1 sizing table for your pipe material. Pick the smallest pipe that carries the load. If the exam gives a floor plan, size each branch — do not size the whole system as one pipe.

    6. Pressure conversions

    • 1 psi = 27.7 in WC
    • Standard residential inlet pressure: 7 in WC (natural gas), 11 in WC (propane)
    • Manifold pressure at appliance: check rating plate — typically 3.5 in WC (NG) / 10 in WC (LP).

    7. Regulator relief venting

    • Vent must terminate outdoors.
    • 3 m (10 ft) from any building air intake, source of ignition, or window that opens.
    • Screened to prevent insect / debris entry, oriented to prevent rain intrusion.

    8. Ontario-specific rules (O. Reg 212/01)

    • Only a TSSA-certified gas technician (G3, G2, or G1 within scope) may install, service, or alter gas piping and appliances.
    • G3 scope: appliances up to 400,000 BTU/h, under direct supervision.
    • G2 scope: appliances up to 400,000 BTU/h, unsupervised.
    • G1 scope: no BTU/h limit, industrial and commercial.
    • All work must be recorded on the appropriate TSSA installation record.

    9. Exam-day tactics

    • Answer easy questions first. Flag calculations and code-lookup for a second pass.
    • On pipe sizing: draw the floor plan on scrap paper before you touch the table.
    • If two answers look right, the more specific one usually wins.
    • "All of the above" is right more often than random. "None of the above" is a trap.
    • Read every question twice. TSSA loves the words except and not.

    FlamePath is independent. It is not affiliated with or endorsed by TSSA, CSA, or any Ontario government body. Always defer to the current published code and to the appliance manufacturer's instructions.

    Free download

    Want the printable PDF version?

    Same content, formatted as a single-page PDF you can print at 100% and fold into your codebook. We'll email it.

    No spam. Unsubscribe anytime. We never sell emails.

    KEEP GOING

    FREQUENTLY ASKED QUESTIONS

    +Is this cheat sheet enough to pass the TSSA G3 exam on its own?

    No. The cheat sheet is a one-page memory aid for the highest-yield facts — gas properties, clearances, venting categories, and pipe-sizing basics. You still need to practice with real exam-style questions and read CSA B149.1 and O. Reg 212/01. Use it as the last thing you review the night before your exam.

    +Can I bring this into the TSSA exam?

    No. TSSA G3 and G2 exams are closed-book. You can bring an unmarked CSA B149.1 code book only if your test centre allows it. This cheat sheet is a study aid for use before the exam, not during it.

    +What edition of CSA B149.1 does this reference?

    The current edition adopted under Ontario Regulation 212/01. CSA updates B149.1 roughly every 5 years — always confirm the edition referenced on tssa.org for your exam date.

    +Is the cheat sheet free?

    Yes. Enter your email to get the PDF. We use your address to send the sheet and occasional Ontario gas-trade updates. Unsubscribe anytime.

    +What is the default clearance for a Type B vent connector?

    6 inches (150 mm) to combustibles unless the appliance manufacturer specifies otherwise. Always defer to the appliance rating plate and installation manual.

    WRITTEN BY ANTHONY VERRELLI

    TSSA G1 Licensed Gas Technician · 6+ years field experience at Enbridge Gas. Founder of Flamepath. Content mapped to CSA B149.1 and Ontario Regulation 212/01 based on hands-on commissioning, service, and inspection work.