TOPIC WEIGHT BREAKDOWN
Approximate question distribution on EX 9001. Venting alone is a quarter of the exam — drill it first.
Estimate, not official figures: TSSA does not publish per-topic weightings for the G2 exam. The percentages below are our estimate based on the published exam scope and candidate feedback — use them to prioritize your study time, not as an official blueprint.
VENTING SYSTEMS
Categories I-IV identification, common venting rules, termination clearances (windows, soffits, grade, mechanical intakes), B-vent vs PVC vs CPVC vs polypropylene.
CSA B149.1 §8.14, §8.18
COMBUSTION AIR
Confined vs unconfined spaces, two-opening method, single-opening method, direct outdoor air supply, mechanical air supply.
CSA B149.1 §8.4
APPLIANCE INSTALLATION
Clearances to combustibles, accessibility, shutoff valve placement, drip legs, condensate handling.
CSA B149.1 §7
PIPE SIZING & PRESSURE
Black iron, CSST, copper sizing tables; pressure drop calculations; manifold sizing; meter capacity.
CSA B149.1 §6
CONTROLS & IGNITION
HSI, IPI, DSI sequencing; flame rectification; gas valve types; pressure switches; thermostat wiring basics.
Manufacturer + B149.1 §6.20
HYDRONICS & BOILERS
Near-boiler piping, expansion tanks, aquastats, low-water cutoffs, zone valves, primary/secondary loops.
CSA B149.1 §7.20
CODES & REGULATIONS
O. Reg 212/01 (Gaseous Fuels), TSSA jurisdiction, who can do what work, reporting requirements.
O. Reg 212/01
3 SAMPLE QUESTIONS — REAL FORMAT
Code-application style. Not trivia. This is what EX 9001 looks like.
Q1. A natural gas furnace is installed in a confined space with a volume of 800 ft³. The total input rating of all appliances in the space is 80,000 BTU/h. Using the two-opening method with openings to outdoors, what is the minimum free area of EACH opening?
Show answer & code reference →
B149.1 §8.4.4 — for outdoor air via two openings, 1 sq inch per 4,000 BTU/h total input. 80,000 ÷ 4,000 = 20 sq in. per opening.
Q2. A Category IV appliance is being installed. Which of the following venting materials is NOT permitted?
Show answer & code reference →
B-vent (Type B). Category IV produces positive-pressure, condensing flue gases — requires PVC, CPVC, polypropylene, or AL29-4C stainless. B-vent is for Category I only.
Q3. What is the maximum length of a horizontal vent run permitted before requiring a vertical rise, per manufacturer specs and B149.1 best practice for a Category I appliance?
Show answer & code reference →
Trick question — there's no single B149.1 number. You must follow the appliance manufacturer's installation instructions, which take precedence per B149.1 §4.2.1. Most spec ≤75% of vertical height.
WHERE CANDIDATES LOSE POINTS
SLOW CODEBOOK NAVIGATION
They know the material. They just can't flip to §8.4.4 in under 30 seconds. Drill the table of contents.
CONFUSING CATEGORY II VS IV VENTING
Both can be condensing. The difference is pressure (negative vs positive). Memorize the matrix.
MANUFACTURER INSTRUCTIONS VS CODE
B149.1 §4.2.1: manufacturer specs override generic code minimums. Many candidates miss this.
MATH ERRORS ON COMBUSTION AIR
Two-opening method, single-opening, direct outdoor — three different formulas. Confusing them costs 4-6 questions.